Grabber issues

Last modified by Lev Andronov on 2025/02/04 12:22

This is a comuluative page contains known issues with KAYA Frame Grabbers.

Max. PCIe device in system

  • Vision Point has a limit of 12 PCIe devices in one system.
  • Vision Point II has not limit for the PCIe devices.

Komodo CXP

  • The first generation Komodo grabbers are not longer supported by Vision Point. The latest version to support is Vision Point 2024.1 SP2.

Komodo II CXP

  • Komodo II CXP is not able to process 2x Iron661 cameras with 2 links each at CXP-12 speed: one of the camera should be switched to CXP-6 because of the bandwidth exceedance

Komodo III CXP

This section contains known issues for device with driver id 610\612 which is known as "Komodo III CXP Frame Grabber".

  • Komodo III is not supported by Vision Point
  • Komodo III should be updated to firmware 8.2.1 in order to work with Vision Point II

Known issue

Vision Point reinstallation with Komodo III can cause a PC reboot on a specific motherboard model (ASUS Pro WS WRX80E-SAGE SE WIFI).

Please follow these steps to work around this issue:

  1. In Device manager disable the Komodo III device
  2. Uninstalled and than install Vision Point
  3. Reboot PC
  4. In Device manager enable the Komodo III device
  5. Start using Vision Point